Pump:
Diaphragm pressure pump
End pressure + 20 % - 2,8 (0,27) mWs (bar)
Free yield - 168 l/h
Built-in filter
Reference air:
Measuring range (adjusttable with valve)
1,6 l/h to 16 l/h
Accuracy class 2,5 VDI/VDE 3513, sht. 2
Readoff lenght 100 mm
Rising air:
Measuring range (adjustable with valve)
10 l/h to 100 l/h
Accuracy class 2,5 VDI/VDE 3513, sht. 2
Readoff length 100 mm
Built-in non-return valve |
Measuring principle:
Floating body
Switch cabinet:
Wall housing, steel - plated
RAL 7032 pebble grey
Protection type IP 55
Cable and hose glands PG 13,5
Dimensions:
380 x 300 x 210 mm (W x H x D)
Air connections:
Hose nozzles for 4 mm I.D.
Electr. data:
Pump, selenoid valve - 230 V / 50 Hz
Power consumption:
approx. 12 VA
Ambient temperature:
-10 to 50 degrees Celsius |