Overview of types:
| Type |
Input |
Output |
| 1: |
L-probe, thermocouple Type "K" or "S" |
0...1300 mV, Zr02 - probechrakteristik |
| 2: |
L-probe, thermocouple Type "K" or "S" |
C-level (0...20 mA) (0...10 V) |
| 3: |
ZrO2-,, thermocouple Type "K" or "S" |
C-level (0...20 mA) (0...10 V) |
| 4: |
CO2 - analyzer, thermocouple Type "K" or "S" |
C-level (0...20 mA) (0...10 V) |
C-level measurement (principle):
| Measured: |
| Temperature, ref. pt temperature, O2 content via, ZrO2
or L-probe |
| Output: |
| C-level (0...20 mA) |
| Parametr (fixed value): |
| CO content, correction data |
| Actual value correction: |
| To eleminate measuring in the furnance, a correction of the calculated
C-level which is based on foil samples, is provided. |
Technical Data (basic unit):
Housing:
Control panel housing Made of sheet-steel. Fixed trought bracket.
| Dimensions: |
| Front: panel: |
144 x 144 (H x W) |
| Housing with surrender connector: |
109 x 109 x 205 (H x W x D) |
| Cut-out in front panel: |
113 x 113 (H x W) |
| Weight: |
| approx. 1,5 kg |
| Protection type: |
| IP 50 according to DIN 40050 |
| Climate: |
|
| Storage: |
-10...+70 °C |
| Operation: |
0...+50 °C |
| 5...95 % relative humidity, non condening |
|
|