Overview of types:
Type |
Input |
Output |
1: |
L-probe, thermocouple Type "K" or "S" |
0...1300 mV, Zr02 - probechrakteristik |
2: |
L-probe, thermocouple Type "K" or "S" |
C-level (0...20 mA) (0...10 V) |
3: |
ZrO2-,, thermocouple Type "K" or "S" |
C-level (0...20 mA) (0...10 V) |
4: |
CO2 - analyzer, thermocouple Type "K" or "S" |
C-level (0...20 mA) (0...10 V) |
C-level measurement (principle):
Measured: |
Temperature, ref. pt temperature, O2 content via, ZrO2
or L-probe |
Output: |
C-level (0...20 mA) |
Parametr (fixed value): |
CO content, correction data |
Actual value correction: |
To eleminate measuring in the furnance, a correction of the calculated
C-level which is based on foil samples, is provided. |
Technical Data (basic unit):
Housing:
Control panel housing Made of sheet-steel. Fixed trought bracket.
Dimensions: |
Front: panel: |
144 x 144 (H x W) |
Housing with surrender connector: |
109 x 109 x 205 (H x W x D) |
Cut-out in front panel: |
113 x 113 (H x W) |
Weight: |
approx. 1,5 kg |
Protection type: |
IP 50 according to DIN 40050 |
Climate: |
|
Storage: |
-10...+70 °C |
Operation: |
0...+50 °C |
5...95 % relative humidity, non condening |
|
|